WhoKnew Views™ | Maximum Display Value

Skip to main content
Table of Contents
Print

Setting the Ceiling for Padded Views

The Maximum Displayed Views setting (max_display) sets the ceiling for your padded views. When the padded portion of your view count reaches this number, the system automatically stops adding more padding. Real views, however, continue counting on top without any restrictions.

💡 Key Concept: This setting controls the padded portion only—your actual customer traffic is never limited by this ceiling.

📍 Where to Find This Setting

The location depends on your chosen capacity strategy:

🎯 With Simple Ceiling Selected

  1. Navigate to WooCommerce → WhoKnew Views → General
  2. In the Capacity Management section, ensure Simple Ceiling is selected
  3. The Maximum Displayed Views field appears in a prominent blue-bordered box

🚀 With Smart Management Selected

  1. Navigate to WooCommerce → WhoKnew Views → General
  2. In the Capacity Management section, ensure Smart Management is selected
  3. The field appears below the Soft Cap field (must be ≥ Soft Cap)

📊 The Official Description

From the plugin settings page:

“Sets the ceiling for padded views (not real views). When padded views reach this number, the system stops adding more padding automatically. As views naturally decay below the ceiling, padding automatically resumes. Real views always count on top.”

⚙️ How It Works

📐 The Ceiling Check Formula

Padded Views = Baseline Padding + Variation Padding
Ceiling Check:
  IF (Baseline + Variations) >= max_display
    THEN stop adding new variations
    BUT real views continue counting
Display Formula:
  Display = min(Padded, max_display) + Real Views (unlimited)

📈 Practical Example

ComponentValueNotes
Max Display1,500Your ceiling setting
Baseline Padding250Permanent floor
Variation Padding1,250Accumulated from traffic
Total Padded1,500At ceiling ✓
Real Views500Actual visitors
Display Count2,000Padded + Real

✅ Key insight: Even though padded views hit the 1,500 ceiling, the 500 real views bring the total to 2,000. Real traffic is never restricted.

🔄 The Automatic Cycle

Phase 1: Growth 📈

  • Baseline padding is set on first view (permanent)
  • Each visitor triggers variation padding (1-12 views)
  • Variations accumulate at full speed
  • Total padded views grow toward ceiling

Phase 2: Ceiling Reached 🛑

  • baseline + variations >= max display
  • New variations are blocked (variation = 0)
  • Real views continue counting on top
  • Display = ceiling + all real views

Phase 3: Natural Decay 📉

  • Variation timestamps exit the view window
  • Expired variations are automatically removed
  • Padded count drops below ceiling

Phase 4: Resume ✅

  • Next visitor triggers ceiling check
  • baseline + variations < max display
  • New variations added normally
  • Cycle repeats

🔗 Relationship with Other Settings

📊 max_display vs min_display

SettingRoleDefault
min_displayFloor (lowest possible)77
max_displayCeiling (highest for padding)1,373

⚠️ Validation: min_display must be ≤ max_display. If you enter conflicting values, they’re automatically swapped.

📊 max_display vs soft_cap

When Smart Management is enabled:

  • soft_cap = Total display limit (padding + real views)
  • max_display = Must be ≥ soft_cap
  • If you set max_display below soft_cap, it’s auto-adjusted upward

From the settings description:

“IMPORTANT: If Soft Cap is enabled, Maximum Displayed Views MUST equal or exceed the Soft Cap for slowdown zones (85%/95%) to function correctly.”

📊 max_display vs base_random_max

  • base_random_max = Maximum starting baseline
  • max_display = Maximum total padded views
  • Logic: max_display should be > base_random_max to allow growth room

🎯 Use Cases from the Plugin

The settings page outlines two primary use cases:

Use Case 1: Simple Ceiling (Soft Cap Disabled)

“If you want to slow growth without a hard limit on total views, use this alone (disable Soft Cap).”

  • ✅ Padded views cap at max_display
  • ✅ Real views grow unlimited on top
  • ✅ No percentage-based slowdowns
  • ✅ Recommended for most stores

Use Case 2: Smart Management (Soft Cap Enabled)

“If you want automatic management to never exceed a specific total, enable Soft Cap below.”

  • ✅ Total display controlled by soft_cap
  • ✅ max_display must be ≥ soft_cap
  • ✅ Graduated slowdown zones (85% → 95%)
  • ✅ For low-traffic stores needing strict believability

📋 Tooltips from the Interface

Different contexts show different tooltip messages:

LocationTooltip Text
Simple Ceiling Mode“The ceiling where padded views stop growing. Real views continue unlimited.”
Smart Management Mode“The total ceiling for displayed view count (real + padded). Must be greater than or equal to the Soft Cap value above.”
Products Page Modal“The maximum padded views allowed (ceiling for the padded portion). Example: 200 real + 500 max = 700 total.”

⚙️ Failsafe Trimming

The system includes an automatic failsafe that triggers if padded views somehow exceed the ceiling (e.g., race conditions):

// Failsafe check after variation processing
if (total_padded > max_display) {
    excess = total_padded - max_display;
    trim_oldest_variations(product_id, excess);
    // Removes oldest variation timestamps first
}

This ensures the ceiling is always respected, even in edge cases.

📊 Default Value

SettingDefaultNotes
Maximum Displayed Views1,373Matches default soft_cap
Starting View Count (Min)96Baseline floor
Starting View Count (Max)178Baseline ceiling

📝 Why 1,373? This default is calibrated for the “Default” preset, providing substantial growth room while maintaining believability for moderate-traffic stores.

🎯 Best Practices

✅ Do This

  • Leave room for growth: Set ceiling well above your starting range
  • Match your niche: Luxury stores = lower ceilings; high-volume = higher
  • Consider view window: Longer windows accumulate more variations
  • Use product overrides: Bestsellers can have higher ceilings than new listings

❌ Avoid This

  • Ceiling = Starting range: Products will be stuck at their initial value
  • Ceiling < Soft Cap: Creates validation errors (auto-adjusted)
  • Massive ceilings for small stores: 10,000 on a 5-visitor/day store looks obvious
  • Ignoring real traffic patterns: Ceiling should reflect believable growth

🔧 Product-Level Overrides

You can set different ceilings for individual products:

  1. Go to WooCommerce → WhoKnew Views → Products
  2. Click Activate on any product
  3. Choose your strategy (Simple Ceiling or Smart Management)
  4. Set the Maximum Displayed Views for that product
  5. Click Apply Settings

💡 Pro Tips

  • 🎯 Use the Simulation Engine: Preview how different ceiling values affect growth
  • 📊 Monitor decay patterns: If ceiling is never reached, it might be too high
  • 🔄 Plan for growth: Set ceiling above current needs for future expansion
  • 📋 Match presets: Built-in presets have pre-calibrated ceiling values

Share